
Explore wind generation for your site with the Smaraad ST-1KW Tulip vertical-axis wind generator. Choose a listed 24V or 48V configuration and White, Purple, or Blue finish to suit your project. Its stated 1kW rating applies at a listed wind speed of 13 m/s, not continuous output in every breeze. The mounting pole is excluded, so plan the supporting structure and compatible electrical equipment before ordering.
Why Customers Choose This Product
Product Highlights
Vertical-Axis Format
The source identifies the Smaraad ST-1KW as a vertical-axis wind generator. Confirm complete assembly dimensions, weight, mounting details, and clearances before selecting a location.
Rated Output with a Stated Wind Condition
The listing gives 1kW rated power at 13 m/s. Actual output varies with wind at the installed height, turbulence, controls, and electrical losses; the rating is not a promise of daily energy yield or household coverage.
Select the Voltage Configuration
The selector offers 24V or 48V, and the source labels rated voltage as AC. Confirm generator output characteristics and the required wind controller, rectification, battery, and inverter arrangement with a qualified installer.
Specify Your Support Structure
The mounting pole is not included. Obtain manufacturer mounting requirements and a professionally assessed support, foundation, and anchoring plan rather than assuming an existing pole or rooftop is suitable.
Specifications
- Brand referenced
- Smaraad
- Model
- ST-1KW
- Listed vendor
- DONJOHNSTYLE4URHOME
- Design
- Tulip-style vertical-axis wind generator
- Rated power
- 1kW as stated by supplier
- Rated wind speed
- 13 m/s
- Voltage selections
- 24V or 48V; source describes rated voltage as AC
- Startup wind-speed reference
- 2 m/s; rotation does not establish usable electrical output
- Cut-in wind-speed reference
- 4 m/s; output at cut-in not specified
- Rotor diameter
- 1 m (3.28 ft, as listed)
- Blade height
- 1.7 m; overall installed height not supplied
- Color selections
- White, Purple, Blue
- Mounting pole
- Not included
Confirm the exact packing list, turbine weight, output wiring, controller specifications, braking system, maximum operating and survival wind speeds, materials, noise data, and applicable test documentation. No battery capacity, controller, inverter, cables, or installation inclusion is established by the source text.
Ideal For
- Buyers evaluating a listed 1kW vertical-axis turbine.
- Projects with a professionally assessed wind resource and suitable mounting location.
- Customers specifying compatible 24V or 48V wind-generation equipment.
- Installations with a separately planned pole, foundation, and electrical protection.
Important Information
- The mounting pole is excluded. Confirm the turbine interface, pole height, structural loads, foundation, anchoring, rotor clearances, and lifting requirements with qualified professionals.
- The 1kW rating applies at the listed 13 m/s wind speed. No consistent output in varying winds, daily kWh production, energy savings, payback, or whole-home supply is guaranteed.
- Startup at 2 m/s and cut-in at 4 m/s describe different conditions. Do not treat startup rotation as rated output or usable charging.
- Request a verified power curve and assess wind at the planned installation height, nearby obstructions, turbulence, and system losses before estimating generation.
- The source labels the 24V/48V rating as AC. Do not assume direct battery connection or compatibility with a solar charge controller. A qualified electrical professional should specify compatible wind controls, rectification, voltage limits, and battery protection.
- Confirm whether any controller, inverter, battery, mounting hardware, cables, disconnects, or load-control equipment is included; obtain an itemized quote before purchase.
- Obtain manufacturer overspeed protection, braking, shutdown, grounding, lightning protection, inspection, and maintenance instructions. Maximum operating and survival wind speeds are not supplied in the source text.
- Keep people and animals clear of the rotor and installation area. Do not assume rooftop installation, unrestricted weather exposure, or maintenance-free operation is approved.
- Grid connection, export, automatic backup transfer, and existing solar-system compatibility are not established. Have the complete electrical arrangement professionally assessed before connection.
- Confirm applicable site requirements, delivery access, unloading, freight charges, lead time, warranty, return terms, and service support before ordering.
Frequently Asked Questions
Is the mounting pole included?
No. The original listing explicitly excludes the pole. Obtain manufacturer mounting specifications and a professionally assessed support, foundation, and anchoring plan.
When does it produce its listed 1kW?
The source lists 1kW rated power at 13 m/s wind speed. Actual output depends on wind conditions, installation, controls, and losses. No continuous-output or daily-generation guarantee is made.
What is the difference between startup and cut-in wind speed?
The source lists startup at 2 m/s and cut-in at 4 m/s. Startup rotation does not establish usable system output, and no output at cut-in is specified. Request the model's verified power curve.
Can I connect it directly to a 24V or 48V battery?
Do not assume direct connection. The source describes rated voltage as AC. Have a qualified electrical professional confirm compatible wind controls, rectification, battery protection, and the complete wiring arrangement.
Which colors and voltage options are listed?
The selectors list White, Purple, and Blue with 24V and 48V voltage options. Confirm availability, the exact configuration, and included equipment before ordering.
Choose your preferred color and voltage, then confirm the wind resource, support structure, and compatible electrical package. Finalize installation responsibilities and delivery terms before ordering the ST-1KW.
















