Skip to product information
1 of 10

RevX X-FLOW Cold Plunge Filtration System with UV-C

RevX X-FLOW Cold Plunge Filtration System with UV-C

Regular price $800.00 USD
Regular price $1,000.00 USD Sale price $800.00 USD
Sale Sold out
Shipping calculated at checkout.
Quantity
View full details
  

Build a more organized water-care setup around your compatible cold plunge with the RevX X-FLOW. This preassembled filtration unit combines a listed 200W circulation pump, 18W UV-C equipment, and a 10-inch pleated sediment cartridge. Confirm flow requirements and plumbing compatibility before connecting it to your tub or chiller; filtration is not a substitute for a complete water-care routine.

Why Customers Choose This Product

  • 200W pump with listed heat sink.
  • 20-micron pleated cartridge reference.
  • 18W UV-C equipment.
  • Preassembled unit as described.
  • Listed 1-inch barb connections.

Product Highlights

Water Circulation

The source lists a 200W pump with a heat sink. Actual circulation depends on tubing, elevation, filter condition, and connected equipment; the source's conflicting flow figures require clarification.

Pleated Sediment Cartridge

A 10-inch, 20-micron pleated cartridge is listed for debris filtration. Confirm cartridge dimensions, nominal versus absolute rating, replacement part number, and approved cleaning procedure.

UV-C Equipment

An 18W UV-C unit is included in the described system. Lamp wattage does not establish treatment dose, microorganism reduction, or sterile water; obtain model-specific operating and maintenance instructions.

Preassembled Plumbing Format

The source describes a preassembled unit with 1-inch barb fittings. Match hose size, pressure, flow, seals, and connection layout to your exact tub and chiller rather than assuming universal fit.

Specifications

  • Vendor: RevX Wellness.
  • Model: X-FLOW cold plunge filtration system.
  • SKU: RXW-0536.
  • Pump reference: 200W with heat sink.
  • UV-C unit reference: 18W.
  • Filter: 10-inch pleated cartridge, listed 20-micron rating.
  • Connections: listed 1-inch barbs; compatibility requires verification.
  • Flow discrepancy: approximately 720+ GPH in feature copy versus approximately 2720+ GPH in technical copy. Verified operating flow is unresolved.
  • Protection reference: IPX4-rated components as described; complete-unit rating and scope unconfirmed.
  • Assembly reference: preassembled.
  • Voltage, frequency, current, maximum pressure, water-volume limits, and operating-temperature range: not supplied.
  • Tub, chiller, stacking kit, hoses, clamps, and other installation accessories: inclusion not established.

Ideal For

  • Compatible cold plunge setups needing a separate circulation and filtration unit.
  • Buyers able to verify hydraulic and electrical compatibility before installation.
  • Users prepared to maintain filters, UV-C equipment, water chemistry, and routine cleaning.

Important Information

  • Resolve the 720+ versus 2720+ GPH discrepancy before purchase. Obtain a pump curve and measured system-flow conditions; do not size treatment, plumbing, or a chiller from either unverified number.
  • This is a filtration/circulation product. The source does not establish an included refrigeration chiller, temperature controller, tub, or cooling capacity. A heat sink does not itself chill water or guarantee reduced chiller energy use.
  • Confirm approved tub volume, flow and pressure limits, hose size, priming, installation orientation, suction/return protection, and chiller compatibility with the manufacturer. Do not operate during immersion unless the exact system is approved and installed for that use.
  • The source calls the connections universal, but a 1-inch barb size does not establish universal compatibility. Confirm included hoses, clamps, valves, adapters, seals, and the full packing list.
  • A source update projected a chiller-stacking plumbing kit for late July or early August 2026. That forecast does not confirm present availability, inclusion, model compatibility, or permission to stack. Obtain current instructions before mounting equipment on a chiller.
  • UV-C and sediment filtration do not establish sterile, pathogen-free, drinking-safe, or chemically balanced water. No biofilm-prevention guarantee or elimination of sanitizer, cleaning, and water changes is promised.
  • Follow the complete manufacturer-approved routine for water testing, compatible sanitizer, cleaning, filter servicing, lamp/sleeve maintenance, and water replacement. The source recommends cartridge changes every 2–4 weeks based on use; verify the correct interval for your installation.
  • Never expose eyes or skin to operating UV-C equipment, open energized housings, or bypass shielding or interlocks. Isolate power and follow maintenance instructions before servicing.
  • Have a qualified electrician verify voltage, frequency, current, grounding, ground-fault protection, wet-area clearances, and circuit requirements. Plug-and-play wording does not establish standard-outlet compatibility.
  • IPX4 wording applies to unspecified components in the source, not verified submersibility or unrestricted outdoor exposure of the complete installation. Confirm mounting, weather protection, ambient limits, ventilation, and freeze precautions.
  • The source describes 24/7 and residential/commercial operation without duty-cycle or commercial approval documents. Confirm continuous-use limits, supervision requirements, local facility requirements, and warranty coverage.
  • No recovery, health, purification, quantified energy-saving, or universally safe-operation outcome is promised.
  • Confirm equipment dimensions, net/shipping weight, delivery charges and timing, warranty, return conditions, service support, and replacement consumables before ordering.

Frequently Asked Questions

Does X-FLOW cool the water?

The source describes circulation, filtration, and UV-C equipment, not an included refrigeration chiller or verified cooling capacity. Confirm any separate chiller and its compatibility before ordering.

What is the flow rate?

The source conflicts: feature copy says approximately 720+ GPH, while technical copy says approximately 2720+ GPH. Obtain the correct pump curve and operating-flow conditions before sizing your system.

Does UV-C replace sanitizer and water changes?

No. Follow the manufacturer-approved routine for water testing, compatible sanitizer, cleaning, cartridge and UV-C maintenance, and water replacement. UV-C and sediment filtration do not establish sterile or drinking-safe water.

Will it fit every cold plunge or stack on my chiller?

No universal fit is established. Verify 1-inch barb compatibility, flow, pressure, hose routing, and approved installation. A past stacking-kit launch forecast does not confirm current availability, inclusion, or permission to stack on your chiller.

How often should the filter be replaced?

The source recommends replacing the cartridge every 2–4 weeks depending on use. Confirm the correct replacement cartridge, cleaning method, and service schedule for your water conditions and installation.

Confirm the correct flow specification, tub/chiller compatibility, and installation requirements first. Choose X-FLOW as part of a planned water-care setup with approved treatment and ongoing maintenance.

For recreational cold plunge equipment use, not intended to diagnose, treat, cure, or prevent disease. Consult a qualified healthcare professional before cold-water immersion if pregnant, taking medication, or managing a health condition.